3-d numerical study and comparison of eccentric and concentric annular-finned tube heat exchangers
Farouk Tahrour1, Mounir Aksas2, Abdelmoumene Hakim Benmachiche3, Cherif Bougriou4.
The use of 3-D computational fluid dynamics (CFD) is proposed to simulate the
conjugate conduction-convection of heat transfer problems in eccentric annularfinned
tube heat exchangers. The numerical simulation results allow us to
evaluate the heat transfer coefficient over fin surfaces, the fin efficiency and the
pressure drop. The aim of the present paper is to determine the optimum tube
position in the circular fin that maximizes heat dissipation and minimizes pressure
drop. In addition, this study analyzes the effects of fin spacing and fin tube
diameter on heat transfer and flow characteristics for a range of Reynolds
numbers, 4500≤Re≤22500. A satisfactory qualitative and quantitative agreement
was obtained between the numerical predictions and the results published in the
literature. For small fin spacings, the eccentric annular finned tube is more
efficient than the concentric one. Among the cases examined, the average heat
transfer coefficient of the eccentric annular-finned tube, for a tube shift St
=12
mm and a Reynolds number Re = 9923, was 7.61% greater than that of the
concentric one. This gain is associated with a 43.09% reduction in pressure drop.
Affiliation:
- University of Batna, Algeria
- University of Batna, Algeria
- University of Biskra, Algeria
- University of Biskra, Algeria
Download this article (This article has been downloaded 36 time(s))
|
|
Indexation |
Indexed by |
MyJurnal (2019) |
H-Index
|
0 |
Immediacy Index
|
0.000 |
Rank |
0 |
Indexed by |
Scopus (SCImago Journal Rankings 2016) |
Impact Factor
|
- |
Rank |
Q3 (Engineering (miscellaneous)) |
Additional Information |
0.193 (SJR) |
|
|
|